Changelog
What changed in each release of these docs. The current version is shown in the top bar.
Version numbers follow this pattern: a major version (2.0) for a restructure, a minor version (1.4) when hardware, software or procedures change what you do, and a patch version (1.4.1) for corrections.
2.0.3 (November 18, 2026)
- Fixed the menu on phones and narrow windows: it now opens full height and stays readable.
2.0.2 (November 17, 2026)
- Grounding: connect the P-EDC to a grounded power source and keep it grounded while running; running ungrounded is not supported. Check the Grounded light on the PDU. Added to Before You Start, Power On, Troubleshooting and Specifications.
2.0.1 (November 12, 2026)
- Quick Start videos updated with a new voice-over, on the Quick Start page and in the matching Deploy and Operate steps. The content is the same.
2.0.0 (November 11, 2026)
The guide is reorganized around what you're doing, with fewer, shorter pages.
Structure
- Start Here, then three sections: Deploy (nine steps in order, from site check to HiveSight), Operate and Reference.
- Edition tabs: pick NUC PRO or HR-01-2 once and every page shows the steps for your edition.
- Videos: the Quick Start videos also open inside the matching steps.
- Old links keep working: links to earlier versions of these docs take you to the matching new page.
- New pages: Uplink and Internet, NodeWeaver, Troubleshooting, Support and Warranty, and Shut Down and Pack Up (with storage and routine care).
- Combined pages: related topics now sit together, for example lids, legs and bench in Set Up the Case, and all port maps, outlets and addresses in Ports and Addresses.
- HCI platforms: Proxmox VE, Scale Computing HC3 and Harvester are now listed in the HCI Software table instead of separate pages.
- Switch and PDU: a short page with links to the EnGenius manuals.
- Network diagrams redrawn for both editions.
- The product is called P-EDC (Portable Edge Data Center) throughout.
HiveSight
- Reaching HiveSight: DHCP first, otherwise its own fallback address, listed on your Access & Configuration Sheet. Its name is
hiveradar-edc-<serial6>.local. - Setup wizard steps updated, starting with the licence.
- Connection details for StorMagic, NodeWeaver, Scale Computing and Proxmox, and what HiveSight shows for each.
- StorMagic witness: where to turn it on, and what the nodes need to reach it.
- Updates: they need internet, take up to 30 minutes, and roll back automatically if they fail.
- The network ports HiveSight uses, for sites with firewalls.
Network
- Mako 5600 settings as shipped.
- What needs internet access, feature by feature.
1.4.0 (November 9, 2026)
Corrections and cleanup ahead of the 2.0 restructure.
Changed procedures
- Power on: after plugging in, wait about 60 seconds for the PDU to boot, then press and hold the PDU power button; the outlets switch on one at a time. Compute nodes now start automatically. A new Powering Off section covers the reverse.
- Mako 5600 gateway: powered through the included PoE splitter from switch port 8 (splitter to Mako LAN 1 and DC port). The two-cable method is now a fallback only.
- Gateway timing: we recommend mounting and connecting the gateway before powering on.
- Telescopic pole: twist clockwise to lock and counter-clockwise to unlock. The extension pole screws into the EDC first, with the main pole on top.
- Unboxing: matches the current packaging: open the top of the box and lift the carry case out with two people.
- Transport locks: 2 on the front compute drawer and 4 on the rear storage drawers (2 single-hole, 2 double-hole). The hex key is in the instruction pouch under the rear lid. Refit the locks for courier shipping or long-distance moves.
- Mako 5600 mounting: uses the mount clip from the accessory pouch. The HiveRadar cellular gateway uses its own pole adaptor.
- Finding IP addresses: the EDC has no DHCP server of its own. Use your gateway's or site network's DHCP lease list instead of the switch.
- Short moves while running: allowed if the cables reach, moving slowly with two people.
Corrected facts
- Compute nodes ship installed and tested on every edition, including NUC PRO.
- Weights and dimensions: NUC PRO 92.7 lb, HR-01-2 87 lb, about 110 lb in the box. Closed size 24 × 22 × 10.5 in.
- Lids: named as printed inside them. Lid 1 holds the work surface, EDC support legs and extension pole; Lid 2 is the bench with the bench legs.
- Legs and mast: EDC legs are fixed height (10.6 in), horizontal deployment only. The main pole is 4-section. Measured pole lengths added; up to 8.4 ft from the ground fully deployed.
- Accessory pouch: contents list updated, with gateway-specific items marked. SFP+ transceivers are normally pre-installed.
- EnergyBar LED power module: listed in the lids, with the airline check-in note.
- Switches: standard ECS2510FP (8 × 2.5GbE + 2 × 10G SFP+) or upgraded ECS5512FP (8 × 10GbE + 4 × 10G SFP+), available on all editions with the same cabling.
- PDU: region-specific (100-120 V or 200-240 V), with a detachable cord into a C13 inlet. North America uses NEMA 5-15P, International uses Schuko by default.
- Cooling: fans sit at the back of the top rear drawer and start at about 25 °C. The profile is set with a 3-position switch labelled Eco, Turbo and Balanced. Keep the top drawer clear while running, and close it promptly: pulling it far out stops the fans.
- Drawer and LED power: drawers are powered through their rails. Interior lighting covers the compute and storage racks and drawers; exterior lighting is the HiveRadar logo plate.
- Airflow: front to rear only, no side vents.
- Starlink Mini: stored in the lower rear drawer on NUC PRO only. The HR-01-2 uses the optional Starlink backpack.
- Port maps: NUC PRO: switch port 7 is the HiveSight SBC, port 9 the PDU. HR-01-2: port 3 is the HiveSight SBC, port 4 the PDU, ports 9-10 the nodes' 10G links. On both, port 8 is the gateway or site uplink.
- Batteries: referred to as HiveRadar Off-Grid.
- Support: contact your partner or distributor first. HiveRadar support hours are 9 am to 5 pm Eastern.
- HCI platforms: HiveRadar is authorized to pre-image StorMagic SvHCI and NodeWeaver. Proxmox VE, Scale Computing HC3 and Harvester are validated to run, but not supported by HiveRadar.
- Logins: initial addresses and logins are on your Access & Configuration Sheet (in the envelope and by email). The EnGenius default logins only apply after a factory reset.
- PoE: all RJ45 switch ports supply PoE by default; port 8 is recommended for the gateway or site uplink.
- Top drawer: keep it empty while running, including the accessory pouch.
- Shipping damage: note visible damage on the delivery receipt, report concealed damage within 5 business days, keep the packaging.
- Extension cords: avoid them; if needed, grounded heavy-duty, at least 15 A (NA) or 10 A (INT), never chained.
HiveSight
- The monitoring dashboard is now called HiveSight throughout (previously "EDC Health Monitor"), running on the HiveSight SBC.
- HiveSight can be set up to monitor Proxmox, StorMagic, Scale Computing and NodeWeaver clusters. The connection has to be configured and confirmed; it is not automatic.
- The StorMagic witness is enabled by default when HiveRadar pre-installs StorMagic, or as an add-on in HiveSight.
- UPS connection is through the USB-C port on the keystone panel.
Site
- Cleaner, more professional layout: decorative emojis and icons removed; warnings now use standard callout boxes.
- Search added (runs locally, no external service).
- Light mode can now be selected. Dark stays the default.
- This changelog page.
1.3.1 (September 12, 2026)
- Footer documentation link now points to the HiveRadar website docs hub.
1.3.0 (September 11, 2026)
- Shorter docs URLs (
/docs/edc/<page>), with redirects from the old ones. - Site styling aligned with the HiveRadar brand.
1.2.5 (June 3, 2026)
- HCI section split into one page per platform.
- New step-by-step StorMagic SvHCI guide.
1.2.0 (April 16, 2026)
- HiveRadar yellow branding and restyled footer.
1.1.0 (January 14, 2026)
- Major content, image and flow update, with new network diagrams.
1.0.0 (January 14, 2026)
- First release of the HiveRadar EDC documentation.